Galaxy VM 160 kVA UPS Single 400-400 V with Backfeed protection, Start up 5×8
-
Përshkrimi i produktit
Output
-
Output power capacity
144.0 KWatts / 160.0 kVA
-
Max Configurable Power (Watts)
144.0 KWatts / 160.0 kVA
-
Nominal Output Voltage
400V 3PH
-
Neutral Output Current
231A
-
Output Voltage Distortion
Less than 2%
-
Output Frequency (sync to mains)
50/60 Hz +/-1 Hz
-
Output Frequency (not synced)
50/60 Hz +/-1 Hz
-
Other Output Voltages
380, 415
-
Load Crest Factor
Unlimited
-
Topology
Double Conversion Online
-
Waveform type
Sine wave
-
Overload Operation
10 minutes @ 125% and 60 seconds @ 150%
-
Output Connections(1) Hard Wire 5-wire (3PH + N + G) (Battery Backup)(1) Hard Wire 4-wire (3PH + G) (Battery Backup)
-
Output Voltage THD
< 2% linear load and <3% non-linear load
-
Output Voltage Tolerance
+/- 1% static and +/- 3% at 100% load step
-
Bypass
Built-in Static Bypass
Input
-
Nominal Input Voltage
400V 3PH
-
Input frequency
40 – 70 Hz
-
Input Connections
Hard Wire 3-wire (3PH + G)
-
Input voltage range for main operations
320 – 456 (380V), 320 – 480 (400V), 320 – 498 (415V)V
-
Input voltage adjustable range for mains operation
250 – 600V
-
Input Total Harmonic Distortion
Less than 3% for full load
-
Type of Input Protection Required
gL fuse
-
Maximum Short Circuit Withstand (Icw)
65.0kAmps
-
Maximum Input Current
262.0A
-
Input Power Factor at Full Load
1.0
Batteries & Runtime
-
Battery type
No internal battery – uses external battery system
-
Nominal Battery Voltage
480V
-
End of Discharge Maximum Battery Current
314.0A
-
End of Discharge Battery Voltage
384
-
Efficiency
Communications & Management
-
Control panel
7″ Touch Screen Display
-
Audible Alarm
Audible and visible alarms prioritized by severity
-
Emergency Power Off (EPO)
Yes
-
Available SmartSlot™ Interface Quantity
2
Physical
-
Maximum Height
1970mm , 197.0cm
-
Maximum Width
1052mm , 105.2cm
-
Maximum Depth
854mm , 85.4cm
-
Net Weight
699.0kg
-
Shipping weight
744.5kg
-
Shipping Height
2156mm , 215.6cm
-
Shipping Width
1490mm , 149.0cm
-
Shipping Depth
1052mm , 105.2cm
-
Color
White
Environmental
-
Operating Environment
0 – 40 °C
-
Operating Relative Humidity
0 – 95 %
-
Operating Elevation
0-999.9meters
-
Storage Temperature
-25 – 55 °C
-
Storage Relative Humidity
0 – 95 %
-
Storage Elevation
0-14763.6meters
-
Audible noise at 1 meter from surface of unit
65.0dBA
-
Online thermal dissipation
19650.0BTU/hr
-
Protection Class
IP 20
Conformance
-
Approvals
C-tick, CE, EN/IEC 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, IBC 2012 and CBC2013 to Sds=2.02g, ISTA 2B, OSHPD, RCM, UL 1778, VFI-SS-111
-
Standard warranty
1 year on-site repair or replace with factory authorized Start-Up
General
-
Bypass Connection
Built-in Static Bypass
-
Bypass Protection Device
400.0
-
Max Bypass Input Current
231.0A
-
-